Anritsu MA24106A Guia do Utilizador Página 138

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 224
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 137
10-6 Linearity Test Operational Testing for the MA24106A
10-10 PN: 10585-00020 Rev. C PowerXpert UG
Table 10-5. Measurement Results (2 GHz)
Row
#
Synthesizer
Power Level
Setting
(dBm)
Attenuation
in Reference
Arm
(dB)
A
Reference
Power
Measurement
(dBm)
B
= (A6–A5)
Correction
(dB)
C
= (A+B)
Corrected
Reference Power
Measurement
(dB)
Attenuation
in Test Arm
(dB)
D
MA24106A
Measurement
(dBm)
C–D
Difference
Calculation
(dB)
1 +20 10 0
2 +15 10 0
3 +10 10 0
4+5 10 0
50 10 0
6 adjust per
Step 7e
00 10
7+5 0 0 10
80 0 0 10
9–5 0 0 10
10 –10 0 0 10
11 Max:
12 Min:
13 Delta (E11 – E12):
Table 10-6. Measurement Results (4 GHz)
Row
#
Synthesizer
Power Level
Setting
(dBm)
Attenuation
in Reference
Arm
(dB)
A
Reference
Power
Measurement
(dBm)
B
= (A6–A5)
Correction
(dB)
C
= (A+B)
Corrected
Reference Power
Measurement
(dB)
Attenuation
in Test Arm
(dB)
D
MA24106A
Measurement
(dBm)
E
= (C–D)
Difference
Calculation
(dB)
1 +20 10 0
2 +15 10 0
3 +10 10 0
4+5 10 0
50 10 0
6 adjust per
Step 7e
00 10
7+5 0 0 10
80 0 0 10
9–5 0 0 10
10 –10 0 0 10
11 Max:
12 Min:
13 Delta (E11 – E12):
Vista de página 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 223 224