CC: sensor A range
cc: sensor B range
DD: sensor A filter
dd: sensor B filter
E: measurement units
F: active entry channel
G: OSC status
H: REL mode status
I: trigger mode
J: group trigger mode
K: limits checking status
L: sensor A limits status
M: sensor B limits status
others not used
ST Store setup
Syntax:
ST<val>EN
val:
1 to 10
Remarks:
Stores the present configuration to the selected register.
Example:
To store the current instrument configuration in register 2:
ST2EN
Related
Commands:
RC
TR0 Trigger hold mode
Syntax:
TR0
Remarks:
Sets both channels to trigger hold mode. It does not trigger until it receives
a TR1 or TR2 or GET (group executive trigger), *TRG or TR3 command. If
it receives a TR3 command it reverts back to the trigger mode it was in be
-
fore the TR0 command was sent. If the REM line is low, this command has
no effect.
Related
Commands:
TR1, TR2, TR3, *TRG, Group Execute Trigger (GET), GT0, GT1, GT2
TR1 Trigger immediate
Syntax:
TR1
6-126 ML2430A OM
HP 438A EMULATION COMMANDS GPIB OPERATION