MUX/DEMUX Function (Option)
When the MUX/DEMUX option is added, the multiplexing
structure including the frame alignment signal can be
generated, and multiplexer/demultiplexer measurement can be
performed.
STM
C4
C3
C2 C12
C11
139 Mbit/s
45 Mbit/s
34 Mbit/s
8 Mbit/s
2 Mbit/s
1.5 Mbit/s
N
64k
1.5M6M
45M
2M
8M
34M
139M
Dummy 34M
Dummy 384k
Dummy 1.5M
Dummy 2M
Dummy 6M
Dummy 8M
Dummy 2M
384k
Through Modes
One of the three through modes can be selected: (1)
Transparent,
(2) Overhead/Overwrite, and (3) Payload/Overwrite.
The external DS1/DS3/PDH signal can be added/dropped
Transparent
For in-service monitoring
Rx
Tx
Rx
Tx
Overhead Overwrite
Modification of SOH/POH byte. Addition of various errors/alarms.
Non Frame Pattern/CID Pattern
Frames can be set on/off at all bit rates. CID pattern can
generate or analysis at SDH/SONET measurement.