Anritsu MP1777A Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controlo remoto Anritsu MP1777A. Anritsu MP1777A User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 132
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
Ins traVew “ REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at
www.instraview.com
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment ^
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com ^ for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com
Vista de página 0
1 2 3 4 5 6 ... 131 132

Resumo do Conteúdo

Página 1

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipmentFAST SHIPPING AND DELIVERYTENS OF THOUSANDS OF IN-STOCK

Página 2 - Fourth Edition

Composition of the MP1777A Operation ManualThe operation manual for the MP1777A lO GHz Jitter Analyzer ii, composed of the two \olunies shown below .

Página 3 - Safety Symbols

8.3 Device-Specific Commands: Display : RESult : JITTer : MODE?Command type Response Function Example of useSequential command<mode> = <CHARA

Página 4 - For Safety

Section 8 Device Message Details8.3.5 CALCulate SubsystemThe CALCulate subsystem performs the performance measurement setting and measured result disp

Página 5

8.3 Device-Specific Commands8.3.6 SYSTem SubsystemThe SYSTem subsystem performs control (setting and display) of memory, buzzer and other items.SYSTem

Página 6

Section 8 Device Message Details: SYSTem : MEMory : CLEar <numeric>Command type ParameterFunction Restriction Example of useSequential command&l

Página 7

8.3 Device-Specific Commands: SYSTem ; DATE <numeric1>, <numeric2>, <numeric3>Command type Sequential commandParameter <DECIMAL N

Página 8 - Anritsu Corporation Contact

Section 8 Device Message Detaiis: SYSTem : BUZZer <boolean>Command type ParameterFunction Example of useSequential command<boolean> = <

Página 9 - Notes On Export Management

8.3 Device-Specific Commands8.3.7 STATUS SubsystemThe STATUS subsystem performs control (setting and display) of the status registers.STATUS PRESetOPE

Página 10

Section 8 Device Message Details: STATUS : OPERation : CONDition?Command type ResponseFunction Example of useSequential command<numeric> = <N

Página 11 - Table of Contents

8.3 Device-Specific Commands: STATUS : OPERation: PTRansition <numeric>Command typeSequential commandParameter<numeric> = <DECIMAL NUME

Página 12

Section 8 Device Message Details: STATUS : OPERation : NTRansition?Command type Sequential commandResponse <numeric> = <NR1 NUMERIC RESPONS

Página 13

Table of ContentsFor Safety... HiComposition of the MP1777A Operation Manual.. ISection 1 Ou

Página 14 - Section 1 Outline

8.3 Device-Specific Commands; STATUS ; OPERation ; INSTrument: ENABIe <numeric>Command typeSequential commandParameter <numeric> = <DEC

Página 15 - 1.1 Interface Function

Section 8 Device Message Details: STATUS : OPERation: INSTrument: PTRansition?Command typeSequential commandResponse<numeric> = <NR1 NUMERIC

Página 16 - 1.2 System Setup Example

Appendix A SCPI Error MessagesSCPl specifies codes and messages to correspond to errors as responses to the SCPI command, : SYSTem :

Página 17

A.1 Command ErrorsThe error codes, [-199 and -100], indicate that syntax errors of IEEE488.2 have taken place. In this case, bit 5 of the event status

Página 18 - Section 2 GPIB interface

A.1 Command ErrorsTable A-1 Error Messages of Command ErrorsCodeMessageError Detection Condition-101Invalid characterAn invalid character i.s included

Página 19 - 2.1 GPIB Interface Functions

A.2 Run Time ErrorsThe error codes, [-299 and -200], indicate that errors have taken place in the execution controller. In this case, bit 4 of the eve

Página 20 - 2.2 Device Message List

A.3 Device-Specific ErrorsA.3 Device-Specific ErrorsThe error codes, [-399 and -300J, indicate that the device encountered errors other t

Página 21 - 2.3 Bus Commands

A.4 Query ErrorsThe error codes, [-499 and -400], indicate that the output control queue of the device has encountered errors related to the message e

Página 22 - 2.4 Connecting the GPIB Cable

Appendix BDetails of Initialization Command FunctionsThis section provides explanations of the range of effects of each initialization command on the

Página 23 - 2.5 Setting GPIB

B.1 Initializing BusIFC: Initializes functions of all the devices connected to the GPIB bus line, when the GPIB option ismounted.Initialization of

Página 24 - 2.5 Setting GPIB

Section 6 Status Report... 6-16.1 Configuration of MP1777A Status Registers...6-

Página 25 - 2.6 initializing the Device

B.2 Initializing MessageB.2 Initializing MessageDCL, SDC: Initializes the message exchange among all the devices on GPIB or only specified devices. W

Página 26 - 2.6 Initializing the Device

Appendix B Details of Initialization Command FunctionsB.3 Initializing Device*RST: Initializes the device. (Common to the GPIB and RS-232C options)The

Página 27 - Section 2 GPIB Interface

B.4 Device Status at Power ActivationB.4 Device Status at Power ActivationThe device switches into the following state when the power is activated.(1)

Página 28

Appendix B Details of Initialization Command FunctionsB-6.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.ar

Página 29 - Address 3

Head office address was changedHead office address on the back cover was changed. Please substitute it as the following address. Anritsu Corporation18

Página 30 - ■a rumiaL

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 31

Anritsu Service and Sales offices• ArgentinaMULTIRADIO S.A.Av. Cordoba, 4860 Buenos Aires, C1414BAT, Argentina TEL: +55-4779-5522 FAX: +55-4779-5510•

Página 32 - 3.2.3 <white space>

TEL; +49-211-96855-0 FAX: +49-211-96855-55 BulgariaELSINCO Representation OFFICE Sofiah.e. Strelblshte, sir. Kotlenski Prohod, bl. 96/6/14, BG-1408 S

Página 33 - <PROGRAM MESSAGE UNIT>

ANRITSU COMPANY LTD.(BEIJING REPRESENTATIVE OFFICE)Room 1515, Beijing Fortune Building No. 5 North Road, the East 3rd Ring Road, Chao-Yang District, B

Página 34 - I ; ) is skip.ped

• PakistanAETCOZia Chambers, 25-Mcleod road, Lahore 54000, PakistanTEL: +92-42-7221716, 7311035 FAX: +92-42-7221456 SUPERIOR ELECTRONICS ASSOCIATEDB-9

Página 35 - Example: Sets the data

IV.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 36 - 5PY PROGRAM HEAT

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 37 - _________________________>

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 38 - 3.2.8.2 <program mnemonio

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipmentFAST SHIPPING AND DELIVERYTENS OF THOUSANDS OF IN-STOCK

Página 39 - __________

Section 1 Outline'I’hc MP1777A 10 CiH/ Jitter Analyzer enables automation of measurement when connected with an external controller. The GPIB int

Página 40 - SYSTfDATE 1993,7,15

Section 1 Outline1.1 Interface FunctionThe MP1777A has a connector for remote control on the back face.Remote control of devices is enabled by fittin

Página 41 - 3.3 Program Data Format

1.2 System Setup Example1.2 System Setup ExampleThe figure below slrows an example ol'aystem setup using: an interface.Control from a host comp

Página 42 - 3.3 Program Data Format

Section 1 Outline1-4.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 43 - Integer type

Section 2 GPIB interface[his section provides descriptions ot the CjPIB interlace iunctions and scttitic method in the event that the interiaccused a

Página 44

Section 2 GPIB Interface2.1 GPIB Interface FunctionsThis device only functions as a device and does not function as a controller. Accor

Página 45

MP1777A10 GHz Jitter Analyzer Remote Control Operation Manual Vol. 2Fourth EditionTo ensure that the equipment is used safely, read the "

Página 46

2.2 Device Message List2.2 Device Message ListDevice iiicssaizes are data nicssaees exchanged betv'.cen thie controller and the device via the

Página 47

2.3 Bus CommandsBus commands refer to internal interface communications exchanged when the bus is set to the command mode (when the

Página 48 - U!4 ; M9953 <NL>

2.4 Connecting the GPIB Cable2.4 Connecting the GPIB Cable(Àninect the tiPIli cable to the Gl’lB tangential line located on the btick panel of this d

Página 49 - Example:

2.5 Setting GPIBTo use GPIB as a remote interface, set the device to the local mode and set the address by performing key input

Página 50

(a) [’erforniing tlie operations mentioned in I causes the screen to shift to the Secondary system screen as shown below. Move the black and white rev

Página 51 - 4.2.7 <RESPONSE DATA>

2.6 initializing the DeviceIEEE488.2 stipulates three levels of system initialization: initialization of the bus, message and device.Table 2-6 Types

Página 52 - 5.1 Common IEEE488.2

2.6 Initializing the Device2.6.3 Initializing the Device<RST; Initializaiion of the dcMce by the ^-^RST eommandFunction: Returns the device func

Página 53

Section 2 GPIB Interface2-10.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 54 - 5.1 Common IEEE488.2

Section 3 Listener Input Formatriiis section provides explanations t)l the tormat rif tiie program message th;it the listener (this niettsuritig instr

Página 55 - Clear Status Command

3.1 Listener Input Program Message FormatThe following section shows program messages when, for example, 4 UI is selected for the rece

Página 56

Safety SymbolsTo prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Corporation uses the following safety symbols

Página 57 - Save Command

3.1 Listener Input Program Message FormatThe WKIlTe and RTAD coniniands take tlic foilo\vin>t fonnals.WRITE @Outputs data to the device.i a rumiaLW

Página 58 - *RCL Recall Command

3.2 Functional Elements of Program MessageThis measuring instrument accepts the program message by detecting the terminator located at t

Página 59 - Function

3.2 Functional Elements of Program Message3.2.2 <PROGRAM MESSAGE TERMINATOR>The <PR()CiRAM MESSAGE TERMlNArOR> in the case of using the G

Página 60

Section 3 Listener Input Format3.2.4 <PROGRAM MESSAGE>The <PROGRAM MESSAGE> is defined as follows.The <PROGRAM MESSAGE> is comp

Página 61

3.2 Functional Elements of Program Message3.2.5 <PROGRAM MESSAGE UNIT SEPARATOR>1 he <PR()GRAM MESSAGE L'MT SEPARA'r()R> is def

Página 62 - Section 6 Status Report

Section 3 Listener Input Format3.2.7 <COMMAND MESSAGE UNIT> and <QUERY MESSAGE UNIT>(1) The <COMMAND MESSAGE UNIT> is defined as fol

Página 63

3.2 Functional Elements of Program MessageI'he <QUHRY MHSSACiEi UMT> is defined as follows.<QUERY PROGRAM HEADER> Refer to 3.2.9<P

Página 64 - Definition

3.2.8 <COMMAND PROGRAM HEADER>The <COMMAND PROGRAM HEADER> is defined as follows. The <while space> can be placed before each heade

Página 65

3.2.8.1 <COMMAND PROGRAM HEADER>The <COMMAND PROGRAM HEADI’R> expresses the appiication, f unction and operation of tlie program data to h

Página 66

3.2.9 <QUERY PROGRAM HEADER>The <QUERY PROGRAM HEADER> is defined as follows. The <white space> can be placed before each header.Se

Página 67

AFor SafetyWARNING AALWAYS refer to the operation manual when working near locations at which the alert mark shown on the left is attached. If the ope

Página 68 - INSTrument Status Register

3.2 Functional Elements of Program Message3.2.10 <PROGRAM HEADER SEPARATOR>The <PR()GR.\M HHADhT'! SEF^ARATOK> is tiefined as follov.

Página 69

3.3 Program Data FormatThis section provides explanations of the format of <PROGRAM DATA> illustrated by the functional syntax d

Página 70

3.3 Program Data Format3.3.1 <CHARACTER PROGRAM DATA>I’lie <CHARAC rER PROGRAM DA'I A> expresses a short ninemonic data and is defin

Página 71

Section 3 Listener Input Format3.3.2 <DECIMAL NUMERIC PROGRAM DATA>The <DECIMAL NUMERIC PROGRAM DATA> expresses a numeric value of a deci

Página 72 - Section 7 SCPI Outline

3.3 Program Data Format3.3.3 <BOOLEAN PROGRAM DATA>I'hc <BOOI,liAN PROCiRAM D.\1'A> refers to l!ie program dat:i specified bv S

Página 73 - 7.1 Outline

Section 3 Listener Input Format3-18.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 74 - 7.2 Command Structure

Section 4 Talker Output FormatThis section pro\'ides explanations of tiie format of the response messages to be returned from the talker (dec ice

Página 75

4.1 Talker Output Response Message FormatThe figure below shows responses to the query for the selection of the receiving jitter range

Página 76 - 7.4 Compounding Commands

4.2 Functionai Elements of Response Message4.2 Functional Elements of Response Message4.2.1 <TERMINATED RESPONSE MESSAGE>I'hc < rr.RMIN

Página 77 - 7.5 Parameter

4.2.3 <RESPONSE MESSAGE>The <RESPONSE MESSAGE> is defined as follows.Section 4 Talker Output FormatThe <RESPONSE MESSAGE> is co

Página 78

Battery FluidFor SafetyWARNING A5. DO NOT short the battery terminals and never attempt to disassemble it or dispose of it in a fire. If the ba

Página 79 - 8.1 Response Format

4.2 Functional Elements of Response Message4.2.5 <RESPONSE MESSAGE UNIT>Tlie <R[iSP().\SH MESSAGE ENHA is defined as follows.<RESPONSEDAT

Página 80

4.2.7 <RESPONSE DATA>The shaded sections in the figure below refer to the <RESPONSE DATA> used by this measuring instrument The response

Página 81 - 8.2 Buffer Size Stipulations

Section 5 Common IEEE488.2 CommandsThis section providec descriptions of the common Ii-iTE488.2 commands supported b\' this device. The common co

Página 82 - 8.3 Device-Specific Commands

5.1 Common IEEE488.2The table below lists common IEEE488.2 commands supported by this device.Table 5-1 List of Common IEEE488.2 CommandsSection 5 Com

Página 83 - <Program Query Command>

5.1 Common IEEE488.2IDN? Identification QueryResponseFunciion lixatiiple of use<ARBITRARY ASCII RHSPONSt DA'rA><Name of product nianufac

Página 84 - 8.3.1 INSTrument Subsystem

Section 5 Common IEEE488.2 Commands^CLSClear Status CommandParameterFunctionExample of useNoneClears all the status composition excluding the o

Página 85 - 8.3.2 SOURce Subsystem

5.1 Common IEEE488.2SRE Service Request Enable Command[’arametcrPiinctioii Pxampie of use<DFX'1MAL. NUMf-TRIC PROGRAM DA'1'A>Inte

Página 86

Section 5 Common IEEE488.2 Commands*PSC Power On Status Clear CommandParameterFunctionExample of use<DECIMAL NUMERIC PROGRAM DATA>0 ...

Página 87

5.1 Common IEEE488.2*RCL Recall CommandParameterFunctionExample of use<DECIMAL NUMERIC PROGRAM DATA>Oto 10Calls the memory of a specified

Página 88 - and jitter generation

Sections Common IEEE488.2 CommandsElementFunction(1) CHARACTER RESPONSE DATA Example:ABCDEFGExpresses short mnemonic data.<responsemnemonio(2)NR1 N

Página 89 - Example of use

Changing FuseACleaningACAUTI0N/Æ,t>18 kgHEAVY WEIGHT.Changing memory back-up batteryDisposing the batteriesFor SafetyCAUTION A1. Before changing t

Página 90 - : SUORce : JITTer: RANGe?

5.1 Common IEEE488.2ElementFunction(5) STRINGRESPONSE DATA Example:"1234""ABCD""1234.5"Expresses a character string in d

Página 91 - 8.3.3 SENSe Subsystem

Section 5 Common IEEE488.2 Commands5-10.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 92

Section 6 Status ReportThe configuration of the status registers of the MP1777A conforms to the SCPI stipulations. (SCPI: Standard Com

Página 93 - : SENSe : TELecom : RANGe?

6.1 Configuration of MP1777A Status RegistersSCPI stipulates that the status register configuration must conform to the configuration spe

Página 94 - : SENSe : TELecom : FILTer?

6.1 Configuration of MP1777A Status RegistersStatus registers excluding the registers specified by IEEE488.2 are configured as follows.Condition Tra

Página 95

6.2 Status Registers Specified by IEEE488.2IEEE488.2 specifies the two status registers shown below.Section 6 Status ReportTable 6-2Definitions of St

Página 96

The tables below show the definition of register bit specified by IEEE488.2.Table 6-3 Definition of Status Byte Register Bit6.2 Status Registers Speci

Página 97 - SENSe : MEASure : : STIMe?

6.3 Status Register Specified by SCPiThe following section shows the definition of the register bit specified by SCPI.OPERation Status registerNOT U

Página 98 - 8.3.4 Display Subsystem

6.4 Status Register Specific to MP1777A6.4 Status Register Specific to MP1777AThe following section shows the definition of the device-specific regis

Página 99 - : Display t SETup [¡NAME]?

6.5 Reading, Writing and Clearing Status Registers(1) Reading and writing methodsThe table below shows the methods of reading and writing the details

Página 100 - 8.3 Device-Specific Commands

VIArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 101 - 8.3.5 CALCulate Subsystem

6.5 Reading, Writing and Clearing Status Registers(2) Clearing and resetting methodsThe table below shows clearing and resetting methods of status re

Página 102 - 8.3.6 SYSTem Subsystem

Section 6 Status Report6-10.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Página 103

Section 7 SCPI OutlineThe MP1777A adopts SCPI (Standard Commands for Programmable Instruments) as commands to perform remote control.Th

Página 104

7.1 OutlineSCPl is a device command language defined by the SCPI consortium and is independent from the hardware.SCPI is designed to shorten the peri

Página 105 - : SYSTem : VERSion?

7.2 Command Structure7.2 Command StructureThe SCPI command form a hierarchical structure. Commands are divided into groups, each of whi

Página 106 - 8.3.7 STATUS Subsystem

Section 7 SCPI Outline7.3 Command Description MethodSOURce : TELecom : BRATe <brate> SOURce ; TELecom ; BRATe?SOURce ; TELecom : EQUAlizer <

Página 107 - : ENABIe <numeric>

7.4 Compounding Commands7.4 Compounding CommandsCommands can be compounded by using semi-colon ( ; ) as shown by the example below.The second comm

Página 108

7.5 ParameterThe table below shows types of parameters used by this measuring instrumentThis operation manual expresses parameter types in low

Página 109

Section 8 Device Message DetailsThis section provides detailed explanations of the device messages supported by the MP1777A.Examples of command use an

Página 110 - STATUS : OPERation

8.1 Response FormatThis section explains the format of the response to the query command The format is shown in the table below'.Table 8-1 Respo

Página 111 - : INSTrument: PTRansition?

Equipment CertificateAnritsu Corporation certifies that this equipment was tested before shipment using calibrated measuring mstruinents with direct t

Página 112

8.1 Response FormatTable 8-2 Details of Response FormatTypeFormatExplanation"XXXX"When 0.000 < Value < 3,232 in the 3,200 UI Range UI

Página 113 - A.1 Command Errors

8.2 Buffer Size StipulationsA response in the format explained earlier is sent from the device to the controller. Therefore, the con

Página 114

8.3 Device-Specific Commands8.3 Device-Specific CommandsThe following section provides details of the device-specific commands.As the command descrip

Página 115 - A.2 Run Time Errors

Section 8 Device Message Details <Program Query Command>The details of a response are omitted when a program command to correspond

Página 116 - A.3 Device-Specific Errors

8.3 Device-Specific Commands8.3.1 INSTrument SubsystemThe INSTrument subsystem is used to specify the same setting for the transmission a

Página 117 - A.4 Query Errors

8.3.2 SOURce SubsystemThe SOURce subsystem controls (setting and display) the transmission side.Section 8 Device Message DetailsSOURce—r :TELecom: JIT

Página 118 - Appendix B

8.3 Device-Specific Commands: SOURce : TELecom : BRATe <brate>Command type ParameterFunctionRestrictionExample of useSequential command<brat

Página 119 - B.1 Initializing Bus

Section 8 Device Message Details: SOURce : TELecom ; EQUAlizer <boolean>Command type ParameterFunction Example of useSequential command<boole

Página 120 - B.2 Initializing Message

: SOURce ; TELecom : CLOCk : SOURce?Command type Sequential commandResponse <csource> = <CHARACTER RESPONSE DATA>INT...Inte

Página 121 - B.3 Initializing Device

Section 8 Device Message Details: SOURce : TELecom: OFFSet <numeric>Command type Sequential commandParameter<numeric> = <DECIMAL NUMERI

Página 122

Notes On Export ManagementThis product and its manuals may require an Export License/Approval by the Government of the product’s country o

Página 123

8.3 Device-Specific Commands: SUORce : JITTer: RANGe?Command type Response Function RestrictionExample of useTransmission sequential command<range&

Página 124 - 22 September 2003

8.3.3 SENSe SubsystemThe SENSe subsystem performs control (setting and display) of measurement conditions and reception side.Section 8 Device Message

Página 125

8.3 Device-Specific Commands; SENSe ; TELecom ; BRATe <brate>Command type ParameterFunction Restriction Example of useSequential command<bra

Página 126 - 14 February 2005 L-1

Section 8 Device Message Details: SENSe : TELecom : RANGe <range>Command type ParameterFunction Example of useSequential command<range> =

Página 127

8.3 Device-Specific Commands: SENSe : TELecom : FILTer?Command type Response Function Restriction Example of useSequential command<filter> = <

Página 128 - 14 February 2005 L-3

: SENSe : TELecom : MEASure : PERiod <numeric>, <suffix>Command type Sequential commandParameter <numeric> = <DECIMAL NUMERIC P

Página 129

: SENSe : MEASure : STATe?________________________________________________________________Command type Sequential commandResponse <mestype>, &

Página 130

Section 8 Device Message Details: SENSe : MEASure : : STIMe?Command typeSequential commandResponse<year>, <month>, <day>, <hour&g

Página 131

8.3 Device-Specific Commands8.3.4 Display SubsystemThe Display subsystem performs control (setting and display) of screens.Display : DSELect :SETUP :

Página 132

Section 8 Device Message Details : Display : SETup [¡NAME] <sdisplay>Command type Sequential commandParameter <sdisplay> = <STRING P