Field Strength
Required Equipment
r
Site Master S114C/S332C
r
Portable Antenna
Procedure
Step 1. Use the Antenna Editor feature of the Software Tools to define an antenna (see
page 7-7).
Step 2. Reset the Site Master to the factory default settings if a known starting state is
desired.
If the unit is off, hold down the ESC/CLEAR key while pressing the ON/OFF
key.
If the unit is already on, press the RECALL SETUP key on the data keypad.
When the key is pressed, a Recall Trace selection box appears on the display.
Select setup location 0 to recall the factory preset state.
Step 3. Upload the antenna information to the Site Master (see page 7-7).
Step 4. Connect the antenna to the Site Master.
Step 5.
Press the FREQ/DIST key and select the
CENTER soft key. Enter the center
frequency.
Step 6.
Press the FREQ/DIST key and select the
SPAN soft key. Set the span wide
enough to include the primary channel bandwidth and upper and lower channel
bandwidths.
Step 7.
Press the SWEEP key and select the
RBW and VBW soft keys to set the resolu-
tion bandwidth to 10 kHz and the video bandwidth to 300 Hz.
Step 8.
Press the SWEEP key and select the
MEASURE soft key.
Step 9. Select the
FIELD STRENGTH soft key.
Step 10. Press the
SELECT ANTENNA soft key.
Step 11. Use the Up/Down arrow key to choose the desired antenna and select by press-
ing the ENTER key.
Step 12.
To change the unit of measurement, press the AMPLITUDE hard key, then
press the
UNITS soft key and select dB, dBV, dBmV or dBmV using the desig-
nated soft key.
The Site Master will automatically adjust the measurement by the antenna factors selected.
A
FIELD STR icon will appear to the left of the graph and the antenna name will be in the
title bar above the graph.